Retül Bike Fit for Leg Length Discrepancy & Hip Flexion

Optimizing Biomechanics

Retül Bike Fit for Leg Length Discrepancy & Hip Flexion

  • Sport Lab
  • Sport Science

Case Study: Optimizing Biomechanics for Severe Leg Length Discrepancy and Restricted Hip Flexion Using Retül 3D Motion Capture

Clinical Overview & Client Profile

  • Gender: Male
  • Riding Profile: Endurance, group rider for last 2-5 years
  • Anatomical Findings: Right leg structurally shorter ~1.5-inch (approx. 38 mm); restricted right hip flexion (less than 90 degrees), right foot a size smaller than the left foot
  • Chief Complaints of Pain: Shoulders, Low Back, and Feet
  • Initial Setup: Major external cleat lift affixed to the bottom of the right cycling shoe and cyclist wearing the same size shoe on both sides leading to poor cleat position and foot stability.

 

Initial Assessment & Motion Analysis:

Visual and Retül Observations

  • Pelvic Asymmetry: The client sat severely asymmetrically, dropping his left hip completely off the left edge of the saddle. This was a compensatory mechanism to artificially “lengthen” the left leg and cope with the right-side shoe lift.
  • Sagittal Plane Distortion: At the top of the pedal stroke (maximum flexion/12 o’clock position), the right hip ran out of available range of motion.
  • Spinal Compensation: To force the right leg through the top dead center, the client excessively rounded his lumbar spine. This posterior pelvic tilt and spinal flexion created a high-risk zone for lower back injury.

 

Biomechanical Problem Solving: The initial strategy of placing a massive 1.5-inch lift entirely under the right shoe was causing increased hip flexion at the top of the pedal stroke. In cycling, a large shoe lift drastically alters the foot’s arc of rotation. It forces the shorter leg to traverse the exact same circumference as the long leg, but at a radically different hip and knee flexion profile. Because the right hip could not flex past 90 degrees, the combination of the high saddle height (set to the long leg) and the thick right sole caused a catastrophic kinematic breakdown at both the top and bottom of the stroke.

 

Due to differences in size of clients feet, his right shoe was too large and not sufficiently stabilizing the foot inside the shoe. Also, the larger size did not allow for the cleat position to be maintained in proper alignment with the mid forefoot. It was recommended that the client purchase the same shoe in two different sizes to allow for the appropriate fit on the smaller right foot. 

 

Retül Fit Interventions: A multi-step intervention strategy was executed to stabilize the pelvis, respect the hip flexion ceiling, and normalize extension.

  • Deconstructing and Reducing the Shoe Lift
  • Action: Stripped the 1.5-inch external lift. Replaced it with a split solution: a moderate 15 mm external cleat shim combined with internal heel/forefoot wedging and custom molded insoles.
  • Biomechanical Purpose: The shorter right crankarm inherently acts as an effective leg length accommodator at the bottom of the stroke (the foot does not push down as far). Therefore, the physical shoe lift no longer needed to match the full 1.5-inch discrepancy.
  • Crankarm Shortening (Right Side)
  • Action: Replaced the stock right crankarm with a significantly shorter crankarm (e.g., reducing from 172.5mm to 150mm).
  • Biomechanical Purpose: A shorter crankarm directly opens the hip angle at the top of the pedal stroke. It lowers the knee height at 12 o’clock, allowing the right leg to clear the top dead center without exceeding 90 degrees of hip flexion.
  • Saddle Re-positioning and Pelvic Equalization
  • Action: Raised the saddle 3-5 mm based on client feedback to better balance bilateral knee extension and power transfer with increased pelvic stability
  • Biomechanical Purpose: Raising the saddle was to allow for optimal ability to produce power in the pedal stroke, as the client felt like it was “too low”. The Retul dynamic capture indicated that this change placed both the right and left side in relatively equal knee flexion and knee extension during the pedal stroke. 

 

Post-Intervention Retül Data & Results:

Pelvic Symmetry

  • Before: Severe left-side lateral tilt and rotation.
  • After: Stabilized, square pelvic tracking. The Retül LED markers on the PSIS (pelvis) showed minimal lateral rock.

Right Hip Angle (at 12 o’clock)

  • Before: < 90 degrees (forced lumbar spine compensation).
  • After: 95–98 degrees of open space, fully respecting the structural restriction of the joint.

Spine Profile

  • Before: Chronic lumbar rounding and cyclical straining.
  • After: Neutral spine alignment maintained throughout the entire 360-degree pedal revolution.

Rider Sensation

  • The client reported an immediate cessation of lower back pulling. Power transfer felt balanced between both legs, and the sensation of “fighting the bike” at the top of the pedal stroke was eliminated.

 

Conclusion: This case study demonstrates that structural leg length discrepancies cannot be solved by simply stacking spacers under the short leg’s shoe. When coupled with joint restrictions like limited hip flexion, massive lifts destroy pelvic stability. By altering the rotational mechanics using a shorter crankarm, the fitter accommodated both the short leg and the tight joint simultaneously, unlocking a pain-free, optimized cycling posture that the client was striving for. 

Pre-Fit Posterior View: Notice the left hip “falling off” the saddle causing severe pelvic instability and the extreme external lift on the right shoe. 

Pre-Fit Posterior View

Post Fit Posterior View: Left hip is no longer falling off and there is equal weight bearing of the pelvis to provide increased rider stability. The rider bought new shoes, one size smaller on the right than the left. Added 100% custom molded insoles, varus wedge on the right side, and 15 mm of external shims to the right side. 

Post Fit Posterior View

Pre-Fit Side View: Significant rounding of spine to accommodate hip flexion at the top of the pedal stroke on the right side. Increased reach to the cockpit from spinal rounding.

Postfit Side View
Post Fit Side View: Improved clearance for hip flexion at the top of the pedal stroke, reducing spinal rounding and improving reach to cockpit. 

Subscribe to Our Newsletter